Contact Us

We've got you covered.


For technical enquiries or pricing quotations, during business hours you can reach our team by phone at +44 (0) 1224 707080.


We're here to help.

HAZcool®

HZ1 Tank Shower

Chiller Unit


The HZ1 tank shower chiller unit regulates the temperature of water or fluid.

This ATEX compliant unit is designed for use in hazardous, explosive areas (zone 1 / zone 2). The system is cased in 316L stainless steel to resist corrosion and is designed to be integrated into the shower system with simple interface and installation.


The unit features an upper condenser section, with all other components enclosed within a lower compartment for added weather protection and noise reduction. Water / fluid temperature is regulated automatically between the temperatures of +25°C to +38°C.


The chiller is supplied as a packaged unit, fully tested and charged with refrigerant and does not require a specialist for installation. Once installed, controls are easy to use and maintain reliable automated room-temperature control.


Suitable for

  • offshore
  • marine
  • petrochemical
  • hazardous
  • Benefits

    • Flame-proof: Hermetically-sealed products reduce the risk of ignition in flammable or explosive areas.
    • Compliant: Designed according to an ISO 9001 accredited QMS these products are compliant with IECEX and EU ATEX and PED directives, where applicable.
    • Customisation: When conditions are unique, customisation is possible. Products are adaptable when bespoke features are required.
    • Durable: Manufactured with durable components and cased in 316L stainless steel to promote a long service life.
    • User-friendly: Units are designed for easy installation and do not require specialist installation. Once installed, controls are easy to use.
  • Temperature Regulation

    Fluid Temperature Regulation Range

    • +20°C to +28°C (3kW)

    Unit Operating Limits

    • -5°C to +60°C (3kW)
  • Non-Standard Options

    The following options are available upon request:

    • Special power supply
    • H2S environment suitable
    • IIC compliant
    • Factory acceptance testing (FAT), installation and commissioning
    • Certified to other standards / directives
    • Notified body type approval
  • Applications

    • Safety Showers
    • Eye wash Stations
    • Potable water systems

    For non-hazardous applications, see Climarine® CM1 Fluid Chiller Unit

Placeholder
  • Thumbnails
  • Thumbnails
  • Thumbnails

Download data sheets

HZ1 Range Datasheet
  1. Next HZ2 Rooftop Packaged Air Conditioning Unit